Defining an Answer Choice/Condition


From the Answer Definition screen, you can:

To create a new answer choice or condition:

  1. Click on the audit form to select it.
  2. Select AUDIT CATEGORIES.
  3. Locate the question for which you want to define answer choices.
  4. Select the question by clicking on the REFERENCE, QUESTION TEXT, or TYPE fields associated with the question.

 

The process of creating answer choices varies with the type of question:

RADIO or DROPLIST:

These question types have point values associated with them. You may want to review "Scoring Logic" before assigning point values to these questions.

  1. Click the NEW button located in the Answer Text section of the window.
  2. Enter the answer text for this answer choice.
  3. Enter the number of points earned when this answer choice is selected.
  4. Enter the total number of points possible for this answer choice. When this answer is selected in Mobile Auditor, the value specified here is added to the total points possible for the entire audit.
  5. The CORRECT CHOICE field is used for reporting purposes. Choices designated as CORRECT are considered COMPLIANT, choices designated as INCORRECT are considered NON-COMPLIANT, and choices designated as INFORMATIONAL are considered neither compliant nor non-compliant. Point values are ignored for answer choices designated as INFORMATIONAL.
  6. If you want this answer choice tagged as Critical, select the CRITICAL CHOICE checkbox. This field is also used for reporting purposes.
  7. When this box is selected, this answer appears as the DEFAULT ANSWER when an auditor chooses to display default answers at the beginning of an audit.
  8. The FORCE FLAG drop-down list contains the following options:
  9. If the REQUIRE NOTES* (optional) checkbox is selected, the Notes window opens immediately after selecting this answer choice, prompting the auditor to enter notes. Please note, however, that the auditor may close the Notes window without ever entering any notes. You should inform auditors to always provide notes if, after selecting an answer choice, the Notes window opens automatically.
  10. If the REQUIRE SIGNATURE checkbox is selected, a Signature window opens automatically in Mobile Auditor PC and Mobile Auditor PPC when this answer choice is selected. Once the Signature window opens, a signature IS REQUIRED. (You may want to enable this option, for example, if an answer choice has been tagged as CRITICAL.)
  11. The text entered in the AUDITOR NOTIFICATION* (optional) box is displayed immediately upon selection of this answer choice. It may be used to prompt the auditor with special instructions.
  12. If the ACTION PLAN: ALLOW DEFAULT ACTION PLAN AND DUE DATES form configuration option is enabled, additional fields are provided for defining a default action plan for each answer choice and for specifying the due date.
  13. Click SAVE & RETURN.

NOTE: If the DYNAMIC QUESTION FUNCTIONALITY* (optional) feature is enabled, you can trigger additional questions when this answer choice is selected. However, you may only specify triggered questions when editing an existing answer choice. You must create the answer choice first, save it, and then edit it. (See Editing a Choice/Condition.)

If the DYNAMIC QUESTION FUNCTIONALITY* (optional) feature is enabled, you can trigger additional questions when this answer choice is selected. However, you may only specify triggered questions when editing an existing answer choice. You must create the answer choice first, save it, and then edit it. (See Editing a Choice/Condition.)

 

TEXT

Text questions have no answer choices, and therefore no point values are associated with text questions. The auditor simply enters text into the text entry field.

 

TEMPERATURE or SPINNER

  1. Click the NEW button. The New Condition dialog opens.
  2. Select the appropriate CONDITION from the drop-down list, then define the parameters of the condition.

  3. From the CORRECT drop-down list, select one of the following:
  4. If the REQUIRE NOTES* (optional) checkbox is checked, the Notes window opens immediately after selecting this answer choice, requiring the auditor to enter notes.
  5. If the REQUIRE SIGNATURE checkbox is selected, a Signature window opens automatically in Mobile Auditor PC and Mobile Auditor PPC when this answer choice is selected. Once the Signature window opens, a signature IS REQUIRED.
  6. The text entered in the AUDITOR NOTIFICATION* (optional) box is displayed immediately upon selection of this answer choice. It may be used to prompt the auditor with special instructions.
  7. Click SAVE & RETURN.
The CONDITIONAL CHOICE ENHANCEMENT* option allows you to assign the same parameters to Temperature, Spinner, and Numeric Text questions as you can to other question types, allowing you to assign point values, set force flags, etc.

 

DATE or TIME

Date and Time questions have no answer choices. An auditor selects a date from a calendar or enters a time in an input box for these question types.

PRE-DEFINED COMMENTS

You may pre-define comments that appear in the Notes window associated with the current question. Each comment appears with a checkbox beside it, and the auditor may then simply select all comments that apply. Because audits are often conducted on hand-held devices without keyboards, selecting a predefined comment reduces the amount of time required to add notes to audit questions.

The application allows you to add a predefined comment that contains an HREF tag to a URL. However, if the entire comment is part of the link to a URL (i.e., the entire comment resides within the HREF tags), you will not be able to edit the comment in the future. Once you save the comment, the entire comment becomes a link, so clicking the link later in an attempt to edit it simply takes you to the target of the link. In order to edit a comment that is entirely within a link, you would need to delete the comment and re-enter it again. However, if a portion of the comment is not part of the link, you can click on that portion of the comment in order to select it for editing. You should make sure that your comment always contains at least some text that is not contained within the HREF tags so that you can edit it in the future if it becomes necessary.

To create comments:

  1. Click the NEW button located in the Comment section of the window.
  2. You may add up to five comments at a time.
  3. Click SAVE & RETURN.

You may add as many comments as are necessary. You may add an additional five comments each time you click the NEW button.

 

Using Auditor-defined Comments as Action Plan Items

You can create a pre-defined comment that, when selected in Mobile Auditor PC/PPC, allows the auditor to define a plan of action. When the audit results are uploaded into Mobile Reporter, that action item appears in the Action Plan feedback report.

Before you can create the comment, you must first determine exactly how the Action Item Label has been defined.

  1. In the Setup Options screen, select CONFIGURATION.
  2. In the drop-list at the top of the page, select LABELS.


  3. Locate the ACTION ITEM label in the left column. (It's located in approximately the middle of the list of labels.)

    Now note the entry in the SETTING field. The predefined comment must match exactly the entry in this field. By default, this field contains "Action Item:". You may change this label if you wish, but keep in mind that the comment you create MUST match the entry in the SETTING column exactly.

  4. Click SAVE & RETURN.
  5. In the Setup Options window, navigate back to the question's Answer Definition screen.

  6. Add a comment that matches the Action Item label exactly. Be sure this comment matches the label in the SETTING field exactly.

 

When the auditor selects that comment in Mobile Auditor, that text will display as an Action Item in the Action Plan feedback report.

*This field is optional. Contact your RizePoint representative to enable this option.

 

See also: On-site Corrective Action Planning.